Search results

1 – 5 of 5
Article
Publication date: 17 April 2020

Ankur V. Bansod, Awanikumar P. Patil and Sourabh Shukla

Low nickel austenitic stainless steel (ASS) has attracted much attention worldwide because of its economical price. This study aims to investigate the effect of different…

Abstract

Purpose

Low nickel austenitic stainless steel (ASS) has attracted much attention worldwide because of its economical price. This study aims to investigate the effect of different corrosive environments on the corrosion behavior of chrome-manganese (Cr-Mn) ASS. The tests were carried out as a function of H2SO4 concentrations, temperature and addition of ammonium thiocyanate (NH4SCN) (0.01 M). Potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques were used to study the corrosion behavior of Cr-Mn ASS. It was observed that with increasing H2SO4 concentration, temperature and with the addition of NH4SCN solution, icorr, icrit and ipassive values increased. EIS data show decreasing charge transfer resistance value with increasing concentration and temperature. Higher corrosion rate with increasing temperature and concentration of H2SO4 is related to the anions (SO42−), which is responsible for reducing the stability of passive films. With the presence of 0.01 M NH4SCN thiocyanate (SCN anion), there is a higher dilution of the passive film resulting in a higher corrosion rate. Energy-dispersive spectroscopy (EDS) analysis reveals the adsorption of sulfur on the surface in NH4SCN containing a solution. The significant presence of counter ions and the adsorbed sulfur species on the steel surface play a vital role in corrosion behavior.

Design/methodology/approach

All the experiments were performed on a 3 mm thick sheet of Cr-Mn ASS (202 ASS) in hot rolled condition. The samples were then annealed at 1,050°C for 1 h, followed by water quenching. For microstructural examination, they were electrochemically etched in 10 Wt.% oxalic acid solution at 1 amp for 90 s. A computer-controlled Potentiostat (Biologic VMP-300) was used. After the cell was set up, the working electrode (WE) was electrostatically cleaned at −1 V vs saturated calomel electrode (SCE) for 30 s to remove the air-formed film. Then, WE were allowed to attain stable open circuit potential (OCP) for 1 h, following by the EIS test and potentiodynamic polarization test. The polarization test was started from a cathodic potential (−1.2 V vs SCE) and continued up to an anodic potential (1.6 V vs SCE) a scan rate of 0.1667 mV/s. EIS experiment was conducted on the same instrument by using a sinusoidal AC signal of 10 mV in a frequency range of 1,000,000 to 0.01 Hz at OCP.

Findings

Potentiodynamic polarization graph shows that with the increase in sulphuric acid concentration. Increasing temperature from 20°C to 80°C in 0.5 M H2SO4 solution increases the corrosion rate (icorr) of Cr-Mn ASS. On the addition of 0.01 M NH4SCN to the sulfuric acid solution (0.1, 0.5 and 1 M) the corrosion rate increases drastically almost four to five times. EDS and XRD analysis shows the presence of sulfur over the oxide film and preferential site for dissolution of Cr and Mn at the steel surface when NH4SCN is added to the sulfuric acid solution.

Originality/value

A study on the corrosion behavior of Cr-Mn ASS is scanty according to the author’s knowledge. Therefore, the present study will investigate the corrosion behavior of Cr-Mn ASS on SO4−2 anions, temperature and the addition of SCN ion in sulfuric acid.

Details

Anti-Corrosion Methods and Materials, vol. 67 no. 3
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 25 September 2018

Ankur V. Bansod, Awanikumar P. Patil and Sourabh Shukla

The purpose of the study is to evaluate Cr-Mn ASS weld using different heat inputs for its microstructure, mechanical properties and electrochemical behavior. The microstructural…

Abstract

Purpose

The purpose of the study is to evaluate Cr-Mn ASS weld using different heat inputs for its microstructure, mechanical properties and electrochemical behavior. The microstructural examination used optical and scanning electron microscopy. It was observed that ferrite content decreases with increasing heat input. The length of dendrites, inter-dendritic space and volume of lathy ferrite increase with increasing heat input. The increasing heat input caused grain coarsening near the fusion boundary and produced wider heat-affected zone (HAZ). It also decreases hardness and tensile strength. This is attributed to formation of more δ ferrite in the weld. The electrochemical evaluation suggested that the δ ferrite helps in improving the pitting potential in 3.5 per cent NaCl solution saturated with CO2. Whereas in 0.5-M H2SO4 + 0.003-M NaF solution, higher passivation current density was observed because of dissolution of dferrite. The interphase corrosion resistance decreased with increasing heat input.

Design/methodology/approach

The Cr-Mn austenitic stainless steel or low-nickel ASS was procured in form of 3-mm sheets in rolled condition. The tungsten inert gas welding was performed at three different heat inputs (100 A, 120 A and 140 A), argon as shielding gas with a flow rate of 15 L/min. Different welded regions were observed using optical microscope and scanning electron microscope. Electrochemicals test were performed in solutions containing 3.5 per cent NaCl with saturated CO2 solution and 0.5 M sulfuric acid + 0.003 M NaF at a scan rate of 0.1667 mV/s at room temperature (30 °C ± 1 °C) using a potentiostat.

Findings

The test steel Cr-Mn ASS is suitable with the selected electrode (308 L) and it produces no defects. Vermicular ferrite and lathy ferrite form in welds of various heat inputs. The increase in heat input reduces the formation of lathy ferrite. The width of HAZ and un-mixed zone increases with increase in heat input. The weld zone of low heat input (LHI) has the highest hardness and tensile strength because of higher δ ferrite content and small grain size in the weld zone. The hardness at high heat input (HHI) is found to be lowest because of grain coarsening in the weld. With increase in δ ferrite, the pitting resistance increases. In 0.5-M sulfuric acid + 0.003-M NaF, the increase in ferrite content reduces the passivation current density. Interphase corrosion resistance increases with increase in δ ferrite content as higher per cent degree of sensitization was observed in LHI welds as compared to medium heat input and HHI welds.

Originality/value

This work focuses on welding of ASS by tungsten inert gas welding at different heat inputs. Welding is a critical process for joining metals in most of the fabrication industries and proper heat input is required for getting desired microstructure in the weld metal. This would highly affect the strength and corrosion behavior of the alloy. This paper would give an understanding of how the change in heat input by tungsten inert gas welding affects the microstructural and corrosion behavior in the weld metal.

Details

Anti-Corrosion Methods and Materials, vol. 65 no. 6
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 1 August 2023

Anand Sharma, Sourabh Shukla, Manish Thombre, Ankur Bansod and Sachin Untawale

The purpose of this study is to examine the effects of sensitization on the metallurgical characteristics of weld joints made up of austenitic stainless steel (AISI 316L) and…

Abstract

Purpose

The purpose of this study is to examine the effects of sensitization on the metallurgical characteristics of weld joints made up of austenitic stainless steel (AISI 316L) and ferritic stainless steel (AISI 430), using the gas tungsten arc welding (GTAW) process with ER316L filler wires.

Design/methodology/approach

A non-consumable tungsten electrode with a diameter of 1.6 mm was used during the GTAW procedure. The filler wire, ER316L, was selected based on the recommendation provided in literature. To explore the interconnections among the structure and properties of these weldments, the techniques including scanning electron microscopy and optical analysis have been used. In addition, the sensitization behaviour of the weldments was investigated using the double loop electrochemical potentio-kinetic reactivation (DLEPR) test.

Findings

Microstructural analyses revealed the occurrences of coarsened grains with equiaxed columnar grains and migrating grain boundaries in the weld zone. The results of the DLEPR test demonstrated that heat affected zone (HAZ) of AISI 430 was more susceptible to sensitization than HAZ of AISI 316L. Microstructure analysis also revealed the precipitation of large amounts of chromium carbide at the grain boundaries region of AISI 430 welded steel, causing more sensitization and, as a result, more failure or breaking at the side of AISI 430 weld in the dissimilar weldment of AISI 316L–AISI 430.

Originality/value

The present work has been carried out to determine the appropriate welding conditions for joining AISI 316L and AISI 430, as well as the metallurgical properties of the dissimilar weldment formed between AISI 316L and AISI 430. Owing to the difficulties in measuring the performance of these types of dissimilar joints given their unique mechanical and microstructural characteristics, research on the subject is limited.

Details

Anti-Corrosion Methods and Materials, vol. 70 no. 6
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 9 August 2019

Sourabh Shukla, Awanikumar P. Patil and Ankur Bansod

The purpose of this study is to investigate the effect of prior cold work after annealing and thermal ageing on intergranular corrosion or sensitization of Cr-Mn austenitic…

Abstract

Purpose

The purpose of this study is to investigate the effect of prior cold work after annealing and thermal ageing on intergranular corrosion or sensitization of Cr-Mn austenitic stainless steel (ASS) is necessary. Such a study is particularly important because ASS are mostly used and welded in mill-annealed condition, which is equivalent to fully annealed material with some cold worked (CW).

Design/methodology/approach

The effect of 15% CW of 202 ASS were investigated using microstructural (optical microscope), mechanical (grain size and hardness) and electrochemical methods (double loop electrochemical reactivation [DLEPR]) followed by thermal ageing (800°C, 900°C and 1000°C).

Findings

X-ray diffraction analysis shows the presence of martensite in CW samples. The increase in martensite formation (800°C and 900°C) can be observed with the variation of thermal ageing (TA) duration (1, 2 and 3 h). However, there was decreased in the formation of martensite at the temperature of 1000°C because of martensitic reversal. The DLEPR test result shows higher degree of sensitization (DOS) for 800°C and 900°C but for 1000°C, there was re-homogenization of samples which leads to lower DOS (thermal ageing for 1, 2 and 3 h).

Originality/value

For 300 series steel, there are various literature available for the effect of cold work on mechanical properties and DOS. However, no one has investigated the effect of cold work and thermal ageing on the sensitization of 202 Cr-Mn ASS.

Details

Anti-Corrosion Methods and Materials, vol. 66 no. 6
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 23 September 2021

Sourabh Shukla, Awanikumar P. Patil, Ashlesha Kawale, Anand Babu Kotta and Inayat Ullah

Effect of grain size on degree of sensitization (DOS) was been evaluated in Nickel free steel. Manganese and nitrogen contained alloy is a Ni-free austenitic stainless steels…

Abstract

Purpose

Effect of grain size on degree of sensitization (DOS) was been evaluated in Nickel free steel. Manganese and nitrogen contained alloy is a Ni-free austenitic stainless steels (ASS) having type 202 grade. The main purpose of this investigation is to find the effect of recrystallization on the DOS of stainless steel after the thermo-mechanical processing (cold work and thermal aging).

Design/methodology/approach

In the present investigation, the deformation of 202 grade analyzed using X-ray diffraction (XRD) and microstructural testing. Optical microstructure of Ni-free ASS has been done for cold worked samples with thermally aged at 900°C_6 h. Double loop electrochemical potentiodynamic reactivation test used for findings of degree of sensitization.

Findings

Ni-free ASS appears to be deformed more rapidly due to its higher stacking fault energy which gave results in rapid transformation from strain induced martensite to austenite in form of recrystallized grains, i.e. it concluded that as cold work percentage increases more rapidly recrystallization occurs. XRD results also indicate that more fraction of martensite formed as percentage of CW increases but as thermal aging reverted those all martensite to austenite. So investigation gives the conclusion which suggests that with high deformation at higher temperature and duration gives very less DOS.

Originality/value

Various literatures available for 300 series steel related to the effect of cold work on mechanical properties and sensitization mechanism. However, no one has investigated the effect of recrystallization through thermomechanical processing on the sensitization of nickel-free steel.

Details

Anti-Corrosion Methods and Materials, vol. 68 no. 6
Type: Research Article
ISSN: 0003-5599

Keywords

1 – 5 of 5